# Exercise 2 (ONOS+P4 Tutorial)
The goal of this exercise is to demonstrate how ONOS apps can be used to
control any P4-defined pipeline, even those implementing custom non-standard
protocols.
## Overview
Similarly to exercise 1, in this example we want to provide connectivity between
hosts of a network when using switches programmed with the `mytunnel.p4`
program. Differently from exercise 1, forwarding between hosts will be provided
by the MyTunnel app, instead of Reactive Forwarding. The MyTunnel app provides
connectivity by programming the data plane to forward packets using the MyTunnel
protocol.
Before starting, we suggest to open the `onos/apps/p4-tutorial` directory in
your editor of choice for an easier access to the different files of this
exercise. For example, if using the Atom editor:
```
$ atom $ONOS_ROOT/apps/p4-tutorial/
```
## Protocol overview
The MyTunnel protocol works by encapsulating IPv4 frames into a MyTunnel header
defined as following:
```
header my_tunnel_t {
bit<16> proto_id; /* EtherType of the original
unencapsulated Ethernet frame */
bit<32> tun_id; /* Arbitrary tunnel identifier uniquelly
representing the egress endpoint of the tunnel */
}
```
A switch implementing the MyTunnel protocol can forward packets using three
different forwarding behaviors.
1. **Ingress**: for IPv4 packets received at a edge switch, i.e. the first node
in the tunnel path, the MyTunnel header is applied with an arbitrary tunnel
identifier decided by the control plane.
2. **Transit**: for packets with the MyTunnel header processed by an
intermediate node in the tunnel path. When operating in this mode, the switch
simply forwards the packet by looking at the tunnel ID field.
3. **Egress**: for packets with the MyTunnel header processed by the last node
in the path, the switch removes the MyTunnel header before forwarding the packet
to the output port.
## MyTunnel pipeline overview
The three forwarding behaviors described before can be achieved by inserting
entries in two different tables of `mytunnel.p4`, namely `t_tunnel_ingress` and
`t_tunnel_fwd`.
* `t_tunnel_ingress`: this table is used to implement the ingress behavior. It
matches on the IPv4 destination address (longest-prefix match), and provides
the `my_tunnel_ingress` action, which encapsulates the packet in the MyTunnel
header with a given tunnel ID (action parameter).
* `t_tunnel_fwd`: this table is used to implement both the transit and egress
behaviors. It matches on the tunnel ID, and allows two different actions,
`set_out_port` and `my_tunnel_egress`. `set_out_port` is used to set the
output port where the packet should be transmitted without further
modifications. With `my_tunnel_egress`, the packet is stripped of the MyTunnel
header before setting the output port.
## MyTunnel app overview
To begin, open
[MyTunnelApp.java](./mytunnel/src/main/java/org/onosproject/p4tutorial/mytunnel/MyTunnelApp.java)
in your editor of choice, and familiarize with the app implementation.
For example, if using the Atom editor:
```
$ atom $ONOS_ROOT/apps/p4-tutorial/mytunnel/src/main/java/org/onosproject/p4tutorial/mytunnel/MyTunnelApp.java
```
The MyTunnel app works by registering an event listener with the ONOS Host
Service (`class InternalHostListener` at line 308). This listener is used to
notify the MyTunnel app every time a new host is discovered. Host discovery is
performed by means of two ONOS core services: Host Location Provider and
Proxy-ARP app. Each time an ARP request is received (via packet-in), ONOS learns
the location of the sender of the ARP request, before generating an ARP reply or
forwarding the requests to other hosts. When learning the location of a new
host, ONOS informs all apps that have registered a listener with an `HOST_ADDED`
event.
Once an `HOST_ADDED` event is notified to the MyTunnel app, this creates two
unidirectional tunnels between that host and any other host previously
discovered. For each tunnel, the app computes the shortest path between the two
hosts (method `provisionTunnel` at line 128), and for each switch in the path it
installs flow rules for the `t_tunnel_ingress` table (method
`insertTunnelIngressRule` at line 182), and/or the `t_tunnel_fwd` table (method
`insertTunnelForwardRule` at line 219), depending on the position of the switch
in the path, the app will install rule to perform the ingress, transit, or
egress behaviors.
## Exercise steps
1. **Complete the implementation of the MyTunnel app**:
1. Open [MyTunnelApp.java](./mytunnel/src/main/java/org/onosproject/p4tutorial/mytunnel/MyTunnelApp.java) in your editor of choice.
2. Look for the `insertTunnelForwardRule` method (line 219).
3. Complete the implementation of this method (There's a `TODO EXERCISE`
comment at line 251).
**Spoiler alert:** There is a reference solution in the same directory
as MyTunnelApp.java. Feel free to compare your implementation to the
reference one.
2. **Start ONOS with and all the apps**.
1. On a first terminal window, start ONOS:
```
$ cd $ONOS_ROOT
$ ONOS_APPS=proxyarp,hostprovider,lldpprovider ok clean
```
2. On a second terminal window to **access the ONOS CLI**:
```
$ onos localhost
```
2. **Activate the BMv2 drivers, pipeconf, and MyTunnel app**:
```
onos> app activate org.onosproject.drivers.bmv2
onos> app activate org.onosproject.p4tutorial.pipeconf
onos> app activate org.onosproject.p4tutorial.mytunnel
```
**Hint:** To avoid accessing the CLI to start all applications, you can
modify the value of the `ONOS_APPS` variable when starting ONOS. For
example:
```
$ cd $ONOS_ROOT
$ ONOS_APPS=proxyarp,hostprovider,lldpprovider,drivers.bmv2,p4tutorial.pipeconf,p4tutorial.mytunnel ok clean
```
3. **Check that all apps have been activated successfully**:
```
onos> apps -s -a
```
You should see an output like this:
```
org.onosproject.hostprovider ... Host Location Provider
org.onosproject.lldpprovider ... LLDP Link Provider
org.onosproject.proxyarp ... Proxy ARP/NDP
org.onosproject.drivers ... Default Drivers
org.onosproject.protocols.grpc ... gRPC Protocol Subsystem
org.onosproject.protocols.p4runtime ... P4Runtime Protocol Subsystem
org.onosproject.p4runtime ... P4Runtime Provider
org.onosproject.generaldeviceprovider ... General Device Provider
org.onosproject.drivers.p4runtime ... P4Runtime Drivers
org.onosproject.p4tutorial.pipeconf ... P4 Tutorial Pipeconf
org.onosproject.pipelines.basic ... Basic Pipelines
org.onosproject.protocols.gnmi ... gNMI Protocol Subsystem
org.onosproject.drivers.gnmi ... gNMI Drivers
org.onosproject.drivers.bmv2 ... BMv2 Drivers
org.onosproject.p4tutorial.mytunnel ... MyTunnel Demo App
```
4. (optional) **Change flow rule polling interval**. Run the following
command in the ONOS CLI:
```
onos> cfg set org.onosproject.net.flow.impl.FlowRuleManager fallbackFlowPollFrequency 5
```
3. **Run Mininet to set up a tree topology of BMv2 devices**, on a new terminal
window type:
```
$ sudo -E mn --custom $BMV2_MN_PY --switch onosbmv2,pipeconf=p4-tutorial-pipeconf --topo tree,3 --controller remote,ip=127.0.0.1
```
4. **Check that all devices, link, and hosts have been discovered correctly in ONOS**.
1. To check the devices, on the ONOS CLI, type:
```
onos> devices -s
```
The `-s` argument provides a more compact output.
You should see 7 devices in total. Please note the driver that has been
assigned to this device `bmv2:p4-tutorial-pipeconf`. It means that the
device is being controlled using the driver behaviors provided the BMv2
device driver (which uses P4Runtime) and the pipeconf.
2. Check the links:
```
onos> links
```
The `-s` argument provides a more compact output.
You should see 12 links (the topology has 6 bidirectional links in total).
3. Check the hosts:
```
onos> hosts -s
```
You should see 0 hosts, as we have not injected any ARP packet yet.
5. **Ping hosts**, on the Mininet CLI, type:
```
mininet> h1 ping h7
```
If the implementation of MyTunnelApp.java has been completed correctly,
ping should work. If not, check the ONOS log for possible errors in the
MyTunnel app. As a last resort, please check the reference solution in
the same directory as MyTunnelApp.java and compare that to yours.
6. **Look around**.
1. Repeat step 3.v and 3.vi from exercise one to check the
flow rules in ONOS and on BMv2.
2. Check the hosts in ONOS:
```
onos> hosts -s
```
You should see 2 hosts, h1 and h7.