| IMPORTANT NOTE - read before defining CONFIG_SYS_USE_OSCCLK in your board
 | |
| 		 config file!!!
 | |
| 
 | |
| 
 | |
| WARNING: Wrong settings of this parameter have the potential to
 | |
| damage hardware by running the MBX's CPU at frequencies that exceed
 | |
| it's rating and/or overdriving the it's SPLL!
 | |
| 
 | |
| 
 | |
| Ramblings:
 | |
| 1) Motorola offered 12 different variants of the MBX, 6 823s and 6 860s.
 | |
| 2) Of these 12 variants, only 2 were entry level boards.
 | |
| 3) I believe that the 2 entry level boards were the only ones that
 | |
|    used OSCM clocking. I can't be completely certain of this at this
 | |
|    point.
 | |
| 4) Motorola never offered an MBX that ran faster than 50Mhz.
 | |
| 5) The 10, non-entry level boards, ran at 40Mhz.
 | |
| 6) The EXTCLK input has a minimum clock of 15Mhz for the 823/860.
 | |
| 7) Motorola no longer sells MBXs.
 | |
| 
 | |
| Based on this information, I can surmise that the default power-on
 | |
| reset clocking was one of the following three options.
 | |
| 
 | |
| Multiplier       SPLL Options
 | |
| ------------------------------------
 | |
| 513              OSCM is SPLL input
 | |
| 5                OSCM is SPLL input
 | |
| 1                EXTCLK is SPLL input
 | |
| 
 | |
| The forth option:
 | |
| 
 | |
| 5                EXTCLK is SPLL input
 | |
| 
 | |
| is not possible on MBXs. This is because the minimum EXTCLK input
 | |
| frequency is 15Mhz. 5 * 15Mhz = 75 Mhz. There was no variant that ran
 | |
| above 50 Mhz.
 | |
| 
 | |
| The board I have borrowed definitely uses a multiplier of 1 for
 | |
| EXTCLK and runs at 40Mhz. I even went so far as to put a scope on it.
 | |
| 
 | |
| One of the two default OSCM modes are most likely what was used on
 | |
| the entry level boards to cheapen them by eliminating the external
 | |
| crystal oscillator.
 | |
| 
 | |
| To add insult to injury, the stupid 860 PLPRCR register retains it's
 | |
| multiplication factor through hard resets. You can't clear it out
 | |
| because it is battery backed and once it is set wrong, it stays
 | |
| wrong. The only way to reset it, so that it takes on it's default
 | |
| multiplier is to disconnect all power including external, batteries,
 | |
| as well discharging caps on the board. This precludes the fact that
 | |
| your 860 may be quite DEAD by this time!
 | |
| 
 | |
| If you don't setup the multiplication factor for boards that use the
 | |
| OSCM input, they won't run correctly, but at least they won't be
 | |
| dead.
 | |
| 
 | |
| Addtionally, there is no good way to determine the clock input source
 | |
| from CPU register data. The only way to deal with this is either hard
 | |
| code it, determine the correct value with some rather NASTY timing
 | |
| loops, or try to grok it from external data sources. Motorola
 | |
| firmware opts for the NASTY timing loops, but needs to configure the
 | |
| serial ports to do so.
 | |
| 
 | |
| 
 | |
| You may have a legitimate need to define CONFIG_SYS_USE_OSCCLK if your
 | |
| MBX8xx board is using the OSCM clocking mode.
 | |
| 
 | |
| You better know what you are doing here.
 |