In order to have the possibility to configure the regulators at system
startup through DM support, all LDOs and bucks must be able to be
changeable. Currently there is a limitation to change the values when
the output is enabled. Since the driver is based on the ROHM BD71837 and a
comment that describes a limitation about switching while the output is
enabled can also be found there, the limitation probably comes from this type.
Signed-off-by: Heiko Thiery <heiko.thiery@gmail.com>
Reviewed-by: Fabio Estevam <festevam@denx.de>