	This converts the PLMT driver from the riscv-specific timer interface to be a DM-based UCLASS_TIMER driver. The clock-frequency/clocks properties are preferred over timebase-frequency for two reasons. First, properties which affect a device should be located near its binding in the device tree. Using timebase-frequency only really makes sense when the cpu itself is the timer device. This is the case when we read the time from a CSR, but not when there is a separate device. Second, it lets the device use the clock subsystem which adds flexibility. If the device is configured for a different clock speed, the timer can adjust itself. Signed-off-by: Sean Anderson <seanga2@gmail.com> Reviewed-by: Rick Chen <rick@andestech.com>
		
			
				
	
	
		
			20 lines
		
	
	
		
			473 B
		
	
	
	
		
			C
		
	
	
	
	
	
			
		
		
	
	
			20 lines
		
	
	
		
			473 B
		
	
	
	
		
			C
		
	
	
	
	
	
| /* SPDX-License-Identifier: GPL-2.0+ */
 | |
| /*
 | |
|  * Copyright (C) 2018, Bin Meng <bmeng.cn@gmail.com>
 | |
|  */
 | |
| 
 | |
| #ifndef _ASM_SYSCON_H
 | |
| #define _ASM_SYSCON_H
 | |
| 
 | |
| /*
 | |
|  * System controllers in a RISC-V system. These should only be used for
 | |
|  * identifying IPI controllers. Other devices should use DM to probe.
 | |
|  */
 | |
| enum {
 | |
| 	RISCV_NONE,
 | |
| 	RISCV_SYSCON_CLINT,	/* Core Local Interruptor (CLINT) */
 | |
| 	RISCV_SYSCON_PLIC,	/* Platform Level Interrupt Controller (PLIC) */
 | |
| };
 | |
| 
 | |
| #endif /* _ASM_SYSCON_H */
 |