net: phy: marvell: Do not reset 88e1310 after autoneg
Commit a058052c "net: phy: do not read configuration register on reset", changes the behaviour of the phy_reset function such that the state of the BMCR register is not preserved during reset. Change the config function for the m88e1310 so that it does not do a reset after configuring auto-negotiation. Signed-off-by: Nathan Rossi <nathan@nathanrossi.com> Cc: Joe Hershberger <joe.hershberger@ni.com> Cc: Michal Simek <michal.simek@xilinx.com> Cc: Stefan Roese <sr@denx.de> Acked-by: Michal Simek <michal.simek@xilinx.com> Acked-by: Joe Hershberger <joe.hershberger@ni.com> Reviewed-by: Stefan Roese <sr@denx.de>
This commit is contained in:
parent
79887749f8
commit
08e64cece2
@ -476,10 +476,7 @@ static int m88e1310_config(struct phy_device *phydev)
|
||||
/* Ensure to return to page 0 */
|
||||
phy_write(phydev, MDIO_DEVAD_NONE, MIIM_88E1310_PHY_PAGE, 0x0000);
|
||||
|
||||
genphy_config_aneg(phydev);
|
||||
phy_reset(phydev);
|
||||
|
||||
return 0;
|
||||
return genphy_config_aneg(phydev);
|
||||
}
|
||||
|
||||
static struct phy_driver M88E1011S_driver = {
|
||||
|
||||