9 Commits

Author SHA1 Message Date
Julien Pivotto
bf3c217bbd config: apply retention CLI flags as defaults and update UI on reload
Introduce DefaultTSDBRetentionConfig, populated from CLI flags before any
config file is loaded, so that retention falls back to CLI flags when the
config file has no storage.tsdb section. Config.UnmarshalYAML always injects
a non-nil TSDBConfig with those defaults, removing the need for nil checks in
main.go. ApplyConfig in web.go now propagates retention settings on each
config reload so the runtime info endpoint stays up to date.

Signed-off-by: Julien Pivotto <291750+roidelapluie@users.noreply.github.com>
2026-02-26 16:36:05 +01:00
Ben Kochie
e14795bbf4
Remove copyright date from headers (#17785)
Remove copyright dates from various files as part of [PROM-50].

[PROM-50]: https://github.com/prometheus/proposals/blob/main/proposals/0050-remove-copyright-dates.md

Signed-off-by: SuperQ <superq@gmail.com>
2026-01-05 13:46:21 +01:00
Arthur Silva Sens
ed0de41b73
bugfix: Default OTLP config not respected when otlp: block is unset (#16693)
Co-authored-by: Jan-Otto Kröpke <mail@jkroepke.de>
2025-06-04 22:52:39 +02:00
bwplotka
f44bba31b3 config: Remove validation GetScrapeConfigs; require using config.Load.
We should never modify (or even shallow copy) Config after config.Load;
added comments and modified GetScrapeConfigs to do so. For GetScrapeConfigs
the validation (even repeated) was likely doing writes (because global fields was 0). We GetScrapeConfigs concurrently
in tests and ApplyConfig causing test races. In prod there were
races but likelyt only to replace 0 with 0, so not too severe.

I removed validation since I don't see anyone using our config.Config without Load.
I had to refactor one test that was doing it, all others use yaml config.

Fixes #15538
Previous attempt: https://github.com/prometheus/prometheus/pull/15634

Signed-off-by: bwplotka <bwplotka@gmail.com>
2024-12-11 13:31:01 +00:00
SuperQ
68ba6c1ae5
Add configuration option for GOGC
Add the ability to adjust the `GOGC` variable from the Prometheus
configuration file.
* Create a new top-level `runtime` section in the config.
* Adjust from the Go default of 100 to 50 to reduce wasted memory.
* Use the `GOGC` env value if no configuraiton is used.

Signed-off-by: SuperQ <superq@gmail.com>
2024-06-05 15:23:16 +02:00
tyltr
f97fa2736c remove obsolete build tag
Signed-off-by: tyltr <tylitianrui@126.com>
2024-01-17 22:26:32 +08:00
SuperQ
e167a45c65
Add new Go build tags.
Add new go:build comments based on 1.17 formatting[0].

[0]: https://golang.org/doc/go1.17#gofmt

Signed-off-by: SuperQ <superq@gmail.com>
2021-08-27 10:24:14 +02:00
Andy Bursavich
4e6a94a27d
Invert service discovery dependencies (#7701)
This also fixes a bug in query_log_file, which now is relative to the config file like all other paths.

Signed-off-by: Andy Bursavich <abursavich@gmail.com>
2020-08-20 13:48:26 +01:00
Fuente, Pablo Andres
9eb8c6e1d2 Renaming the config_notwin test to config_default 2017-07-10 11:08:16 -03:00