Change-Id: Ib977f4cf9a59ddec360072891fd803c6f9ee84f1
Injecting optical device annotations and ports works for multi-instance (ONOS-870).
Change-Id: Icdde16ef72fc4e47eec7213250b04902083f0537
- Use subtype() instead of type() inside method
ModMplsLabelInstruction.toString()
- Check whether the MPLS value is negative inside the MplsLabel()
constructor.
Change-Id: I770194774219f0c919474928803e078226f2005d
The APIs are for supporting service data to install on network devices.
This is related to JIRA ticket ID ONOS-869.
Updated API code and added implementation code files.
Modified API for supporting payload abstruction, and added routing mechanism for pushing flow rules to devices.
Added more javadoc, and fixed some minor issues.
Updated javadoc, removed unnecessary method, and test code.
Change-Id: I105defc92a9e01b30601fcb56a9dafa086d4adc0
- aggregate installables into FlowRuleOperations
- added some impl. to SimpleIntentStore
- created Coordinating State
Change-Id: I5b26ec1fdb7aaff9d5da4f21b2d5a249568ac5ac
- use Key class rather than String for intent keys
- add CLI option to specify a string key
- add key field to constructors for connectivity intents
- translate id into a key if no key is specified
Change-Id: I69ffbad93bc3daddf06a67cb0cffa2130e781b37
Work toward ONOS-509
The following treatments are added/implemented:
- IPV6_SRC
- IPV6_DST
- IPV6_FLABEL
Also:
- Renamed L3ModificationInstruction.L3SubType.IP_SRC and IP_DST
to IPV4_SRC and IPV4_DST (for naming consistency).
- Few minor fixes in related code: Javadocs, comments, log messages,
and IP address usage.
Change-Id: I551056f767a37e7cb6ae7d79f4a3929183500b57
The subsystem no longer returns futures for tracking completion of work.
Notifications are explicitely returned via a call back mechanism. Also, the
subsystem is now asynchronous.
Change-Id: I1a4cef931c24820f9ae9ed9a5398f163f05dfbc9
more flowservice improvements
Change-Id: I5c9c1b6be4b2ebfa523b64f6f52e7634b7d3e05f
more flowservice impl
Change-Id: I05f6774460effb53ced8c36844bcda2f8f6c096f
Manager to store functional (at least i believe it)
Change-Id: I09b04989bd1004c98fe0bafed4c76714b9155d53
flow subsystem functional: need to fix unit tests
Change-Id: I1667f25b91320f625a03e5e1d5e92823184d9de0
flow subsystem functional
Change-Id: I429b3335c16d4fc16f5d55f233dd37c4d1d6111d
finished refactor of flow subsystem
Change-Id: I1899abc6ff6a974a2018d936cc555049c70a6804
fix for null flow provider to use new api
Change-Id: If2fd9bd5baf74d9c61c5c8085cef8bc2d204cbdc
Work toward ONOS-509
The following match conditions are added/implemented:
- IPV6_EXTHDR
Also, fixed the match criteria for the optical signal type
to represent unsigned 8 bits integer (per spec).
Change-Id: I925db19cb43c5d9f589c1f090b6a75faabe0a19b
match/action conditions
Fixed the signed/unsigned issue for the match conditions
Also:
* Reordered some of the code in CriterionCodec.java so the order
of handling various Criterion types follows the order as defined in
Criterion.java
- In the process, removed a duplicated entry for Type.MPLS_LABE
- Fixed an issue with TCP/UDP/SCTP ports being accessed as 8-bit integers
instead of 16-bit integers
* Updated some of the unit tests in CriterionCodecTest.java to use
larger integer values that could expose better potential bugs in
the tested code.
Change-Id: I531d13bd258ebc559ce6be716863c01613427a98
- Fixed PushHeaderInstructions bug, where half-baked Ethernet instace was used
only to hold ethernetType. (ONOS-987)
Change-Id: I330a862c8a18206250befbd4e22ee6d189beed83
- Fixed instanceOf with wrong type (ONOS-974)
- Aligned #toString() format to be the same as other instructions
Change-Id: I526c2ef8d92660e0b821a10f0cf87ee72a84cdf3