- aggregate installables into FlowRuleOperations
- added some impl. to SimpleIntentStore
- created Coordinating State
Change-Id: I5b26ec1fdb7aaff9d5da4f21b2d5a249568ac5ac
- use Key class rather than String for intent keys
- add CLI option to specify a string key
- add key field to constructors for connectivity intents
- translate id into a key if no key is specified
Change-Id: I69ffbad93bc3daddf06a67cb0cffa2130e781b37
Work toward ONOS-509
The following treatments are added/implemented:
- IPV6_SRC
- IPV6_DST
- IPV6_FLABEL
Also:
- Renamed L3ModificationInstruction.L3SubType.IP_SRC and IP_DST
to IPV4_SRC and IPV4_DST (for naming consistency).
- Few minor fixes in related code: Javadocs, comments, log messages,
and IP address usage.
Change-Id: I551056f767a37e7cb6ae7d79f4a3929183500b57
The subsystem no longer returns futures for tracking completion of work.
Notifications are explicitely returned via a call back mechanism. Also, the
subsystem is now asynchronous.
Change-Id: I1a4cef931c24820f9ae9ed9a5398f163f05dfbc9
more flowservice improvements
Change-Id: I5c9c1b6be4b2ebfa523b64f6f52e7634b7d3e05f
more flowservice impl
Change-Id: I05f6774460effb53ced8c36844bcda2f8f6c096f
Manager to store functional (at least i believe it)
Change-Id: I09b04989bd1004c98fe0bafed4c76714b9155d53
flow subsystem functional: need to fix unit tests
Change-Id: I1667f25b91320f625a03e5e1d5e92823184d9de0
flow subsystem functional
Change-Id: I429b3335c16d4fc16f5d55f233dd37c4d1d6111d
finished refactor of flow subsystem
Change-Id: I1899abc6ff6a974a2018d936cc555049c70a6804
fix for null flow provider to use new api
Change-Id: If2fd9bd5baf74d9c61c5c8085cef8bc2d204cbdc
Work toward ONOS-509
The following match conditions are added/implemented:
- IPV6_EXTHDR
Also, fixed the match criteria for the optical signal type
to represent unsigned 8 bits integer (per spec).
Change-Id: I925db19cb43c5d9f589c1f090b6a75faabe0a19b
match/action conditions
Fixed the signed/unsigned issue for the match conditions
Also:
* Reordered some of the code in CriterionCodec.java so the order
of handling various Criterion types follows the order as defined in
Criterion.java
- In the process, removed a duplicated entry for Type.MPLS_LABE
- Fixed an issue with TCP/UDP/SCTP ports being accessed as 8-bit integers
instead of 16-bit integers
* Updated some of the unit tests in CriterionCodecTest.java to use
larger integer values that could expose better potential bugs in
the tested code.
Change-Id: I531d13bd258ebc559ce6be716863c01613427a98
- Fixed PushHeaderInstructions bug, where half-baked Ethernet instace was used
only to hold ethernetType. (ONOS-987)
Change-Id: I330a862c8a18206250befbd4e22ee6d189beed83
- Fixed instanceOf with wrong type (ONOS-974)
- Aligned #toString() format to be the same as other instructions
Change-Id: I526c2ef8d92660e0b821a10f0cf87ee72a84cdf3
Work toward ONOS-509
The following match conditions are added/implemented:
- IN_PHY_PORT
- IP_DSCP
- IP_ECN
- METADATA
Change-Id: I6f529ee90b2b9e0d5046f83c034e8be3faf86d8b
Change-Id: I1125fbc23f1e58bcb8aaf5f67c02da610fa7ef25
ONOS-885: Group store interface definition and in-memory store implementation
Change-Id: Id3794bed63785e10ed86c0b5d90bf875d127224c
Work toward ONOS-509
The following match conditions are added/implemented:
- UDP_SRC, UDP_DST
- SCTP_SRC, SCTP_DST
- ICMPV4_TYPE, ICMPV4_CODE
- IPV6_FLABEL
- IPV6_ND_TARGET
- IPV6_ND_SLL
- IPV6_ND_TLL
Also:
* Renamed method
TrafficSelector.Builder.matchInport(PortNumber port)
to
TrafficSelector.Builder.matchInPort(PortNumber port)
(for consistency with the corresponding method(s) elsewhere)
* Reordered the code for some of the existing matching conditions
to follow the order in the OpenFlow spec, so it is easier to
cross-reference such code.
* Added missing Javadoc
* Added few more Criterion.Type values as per OpenFlow spec 1.5.0
Change-Id: I7fc1656f32d8a7280c67d7827e4aa84528b0eafc
Using Flow ID forces a dependency on the Group/App ID.
This reverts commit 38f8c232295c33a455887366469f81c874bdef94.
Change-Id: Ib08166c8f778228ebbb68f98c763fcc57a9d6771
Other changes are caused due to the new method.
Add type() in FlowRule interface to determine the table in which the flow rule need to be set.
Change-Id: I6518a01f4a5fba23f09f70b619f3844b5e33ce8f
- Remove the bounded type parameter for BatchOperationTarget
- FlowRule and Intent don't inherit from BatchOperationTarget
- Remove BatchOperationTarget because nothing depends on it
Change-Id: I3b414d25409e9bbe5de37ffef10b08bc1799be74