onos> ce-evc-list
CarrierEthernetVirtualConnection{
    id=EP-Line-1, cfgId=evpl1, type=POINT_TO_POINT, state=ACTIVE,
    UNIs=[
        CarrierEthernetUni{
            id=netconf:192.168.56.10:830/0,
            cfgId=netconf:192.168.56.10:830/0,
            role=Root,
            refCount=0,
            ceVlanIds=[100],
            capacity=1000000000,
            usedCapacity=3.0E8,
            bandwidthProfiles=[
                CarrierEthernetBandwidthProfile{
                    id=FC-1,
                    type=EVC,
                    cir=3.0E8,
                    cbs=2000,
                    eir=0.0,
                    ebs=0}]},
        CarrierEthernetUni{
            id=netconf:192.168.56.20:830/0,
            cfgId=netconf:192.168.56.20:830/0,
            role=Root,
            refCount=0,
            ceVlanIds=[100],
            capacity=1000000000,
            usedCapacity=3.0E8,
            bandwidthProfiles=[
                CarrierEthernetBandwidthProfile{
                    id=FC-1,
                    type=EVC,
                    cir=3.0E8,
                    cbs=2000,
                    eir=0.0,
                    ebs=0}]}],
    FCs=[
        CarrierEthernetForwardingConstruct{
            id=FC-1,
            cfgId=null,
            type=POINT_TO_POINT,
            vlanId=1,
            metroConnectId=null,
            refCount=1,
            LTPs=[
                CarrierEthernetLogicalTerminationPoint{
                    id=netconf:192.168.56.10:830/0,
                    cfgId=netconf:192.168.56.10:830/0,
                    role=Root,
                    ni=CarrierEthernetUni{
                        id=netconf:192.168.56.10:830/0,
                        cfgId=netconf:192.168.56.10:830/0,
                        role=Root,
                        refCount=0,
                        ceVlanIds=[100],
                        capacity=1000000000,
                        usedCapacity=3.0E8,
                        bandwidthProfiles=[
                            CarrierEthernetBandwidthProfile{
                                id=FC-1,
                                type=EVC,
                                cir=3.0E8,
                                cbs=2000,
                                eir=0.0,
                                ebs=0}]}},
                CarrierEthernetLogicalTerminationPoint{
                    id=netconf:192.168.56.20:830/0,
                    cfgId=netconf:192.168.56.20:830/0,
                    role=Root,
                    ni=CarrierEthernetUni{
                        id=netconf:192.168.56.20:830/0,
                        cfgId=netconf:192.168.56.20:830/0,
                        role=Root,
                        refCount=0,
                        ceVlanIds=[100],
                        capacity=1000000000,
                        usedCapacity=3.0E8,
                        bandwidthProfiles=[
                            CarrierEthernetBandwidthProfile{
                                id=FC-1,
                                type=EVC,
                                cir=3.0E8,
                                cbs=2000,
                                eir=0.0,
                                ebs=0}]}}]}]}