flatcar-scripts/mod_for_factory_scripts/200patchInitScript
Tom Wai-Hong Tam 1e0dcbd15c Reflect the change that moves startx.sh to a new place.
Reflect the change: http://codereview.chromium.org/3277004

BUG=chrome-os-partner:501 fix the unexpected EOF error
TEST=run image_to_usb --factory and start factory ui on a device

Review URL: http://codereview.chromium.org/3262004

Change-Id: Ieec1237d51c0ca3041be7934405ba44b31f04ea6
2010-08-31 05:35:00 +08:00

106 lines
3.0 KiB
Bash
Executable File

#!/bin/bash
# Copyright (c) 2010 The Chromium OS Authors. All rights reserved.
# Use of this source code is governed by a BSD-style license that can be
# found in the LICENSE file.
echo "Applying patch to init scripts."
touch ${ROOT_FS_DIR}/root/.factory_test
patch -d ${ROOT_FS_DIR} -Np1 <<EOF
--- old/etc/init/ui.conf 2010-04-28 21:28:38.886069000 -0700
+++ new/etc/init/ui.conf 2010-04-28 21:29:42.676163000 -0700
@@ -5,7 +5,7 @@
description "Chrome OS user interface"
author "chromium-os-dev@googlegroups.com"
-start on stopping startup
+start on never
stop on starting halt or starting reboot
respawn
EOF
patch -d ${ROOT_FS_DIR} -Np1 <<EOF
diff -Naur old/etc/init/dump-boot-stats.conf new/etc/init/dump-boot-stats.conf
--- old/etc/init/boot-complete.conf 2010-07-21 11:22:30.000000000 +0800
+++ new/etc/init/boot-complete.conf 2010-07-21 22:13:36.000000000 +0800
@@ -7,7 +7,7 @@
# Processing required during boot after login prompt is displayed.
# Primarily, this means calculating boot time statistics.
-start on login-prompt-ready
+start on stopping startup
task
EOF
cat > ${ROOT_FS_DIR}/etc/init/factory.conf <<EOF
# Copyright (c) 2010 The Chromium OS Authors. All rights reserved.
# Use of this source code is governed by a BSD-style license that can be
# found in the LICENSE file.
description "Chrome OS factory startup stub"
author "chromium-os-dev@googlegroups.com"
start on started udev
stop on starting halt or starting reboot
script
cd /usr/local/autotest
eval \$(./site_tests/suite_Factory/startx.sh)
date >> /var/log/factory.log
if [ ! -e factory_started ]; then
touch factory_started
cp -f site_tests/suite_Factory/control .
./bin/autotest control >> /var/log/factory.log 2>&1
else
./tools/autotest >> /var/log/factory.log 2>&1
fi
end script
EOF
cat > ${ROOT_FS_DIR}/etc/init/factorylog.conf <<EOF
# Copyright (c) 2010 The Chromium OS Authors. All rights reserved.
# Use of this source code is governed by a BSD-style license that can be
# found in the LICENSE file.
start on started factory
stop on starting halt or starting reboot
respawn
script
tail -n 48 -F /var/log/factory.log > /dev/tty3
end script
EOF
patch -d ${ROOT_FS_DIR} -Np1 <<EOF
diff --git old/etc/init/software-update.conf new/etc/init/software-update.conf
index 28c9086..9ebf2b9 100644
--- old/etc/init/software-update.conf
+++ new/etc/init/software-update.conf
@@ -7,7 +7,7 @@
#
# when boot reaches login prompt, start up software update check.
-start on stopped boot-complete
+start on never
respawn
EOF
patch -d ${ROOT_FS_DIR} -Np1 <<EOF
diff -Nau old/etc/init/chrontel.conf new/etc/init/
--- old/etc/init/chrontel.conf 2010-08-05 16:32:55.000000000 -0700
+++ new/etc/init/chrontel.conf 2010-08-05 16:32:45.000000000 -0700
@@ -7,7 +7,7 @@
# start as early as possible to allow login screen on hdmi
# Need udev to have connected the i2c before we can use it
-start on started udev
+start on never
stop on starting halt or starting reboot
# sadly, these can't reference each other.
EOF